Lightening - Light Bar Inoperative or Loses Intensity

TECHNICAL

Bulletin No.: 09-08-42-005A

Date: January 29, 2010

Subject: Driver/Passenger Door Accent Lighting - Light Bar (Pipe) Inoperative or Loses Intensity (Check Light Bar (Pipe) Attachments, Replace
Harness if Necessary)

Models:

2010 Chevrolet Camaro
Equipped with Light Piped Door Trim (RPO FCR)

Supercede:
This bulletin is being revised to update the repair procedure and to add parts and labor information. Please discard Corporate Bulletin Number
09-08-42-005 (Section 08 - Body and Accessories).

Condition

Some customers may comment that the accent lighting on the door trim panel loses intensity and does not carry on across to the instrument panel.

Cause

The normal operation of the door accent lighting is that the light will be brightest at the rear of the door panel and gradually lose intensity until
approximately 76 mm (3 in) (1) from the front edge of the trim panel. The lighting does not carry on to or across the instrument panel. If the light stops at
the center of the door (2), proceed with this bulletin.

Correction

Important
Do not replace the door trim panel to correct illumination concerns.

If the light stops at the center of the door, remove the trim panel and make sure the light bar (pipe) is in the channel, has not dipped down and is in it's
retaining clips (2) and the end cap (1) is properly installed. To verify normal operation, apply 12 volts to the connector and make sure the light is
brightest at the rear of the panel and gradually dims towards the front of the door panel.

If the light bar (pipe) is not illuminated the full length, is noticeably different from side to side or inoperative, replace the lamp-harness assembly. There
are two different part numbers based on the illumination color of the lamp.

Lightening - Light Bar Inoperative or Loses Intensity|Page 11351 > < Lightening - Light Bar Inoperative or Loses Intensity|Page 11345