Cavalier L4-2.2L VIN 4 (1998)
Case: Service and Repair
3T40 Automatic Transaxle
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
2. Remove the transmission bracket.
3. Remove the valve body cover. Refer to Valve Body Cover Replacement.
4. Disconnect the TCC wire from the case connector.
5. Remove the control valve body bolts.
6. Remove the control valve body from the oil pump.
IMPORTANT: Do not lose the check balls.