Cavalier/Z24 L4-138 2.3L DOHC VIN D MFI (1995)
Audible Warning Device: Description and Operation
Key-In-Ignition Chime
Voltage is applied at all times to Conn C2 term "D" of the Multi-function Alarm Module through the ALARM Fuse. When the key is in the Ignition and
the LH front door is open, Conn C1 term "H" of the Multi-function Alarm Module is grounded. This sounds the chime.