Audible Warning Device: Description and Operation
Key-In-Ignition Chime

Voltage is applied at all times to Conn C2 term "D" of the Multi-function Alarm Module through the ALARM Fuse. When the key is in the Ignition and
the LH front door is open, Conn C1 term "H" of the Multi-function Alarm Module is grounded. This sounds the chime.