Cobalt L4-2.0L SC VIN P (2005)
4. Reposition the hose clamp to secure the hose using J 38185.
5. Notice: Refer to Fastener Notice in Service Precautions.
Install the surge tank nut.
^
Tighten the surge tank nut to 10 Nm (89 inch lbs.).
6. Install the underhood electrical center.
7. Install the surge tank inlet hose to the surge tank.
8. Reposition the hose clamp using J 38185 to secure the hose.
9. Fill the cooling system.