Cobalt L4-2.0L SC VIN P (2005)
10.
Install a new seal washer to the compressor hose. Refer to Sealing Washer Replacement.
11.
Install the compressor hose and nut to the evaporator hose.
Tighten
Tighten the nut to 20 N.m (15 lb ft).
12.
Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
13.
Leak test the fittings using the J 39400-A.