1. Install the recirculation actuator.

IMPORTANT:  The key should be in the OFF position when connecting the electrical connectors to ensure proper calibration.

2. Install the recirculation actuator screw.

Tighten the screw to 2.2 N.m (19 lb in).

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Install the recirculation electrical connector.
4. Install the I/P retainer.
5. Install the fuse labeled HVAC CTRL (BATT).
6. Start the engine and let run for one minute.

IMPORTANT:  Do not adjust any controls on the HVAC control assembly while the HVAC control assembly and actuators are calibrating. If
interrupted improper HVAC performance will result.