chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 10393 > < Initial Inspection and Diagnostic Overview|Page 10391
Page 6
background image

The shown table will be used to measure the resistance of the sensor and compare it with the actual ambient temperature. The mirror's temperature
accuracy should be within 5 degrees of the actual temperature. The actual temperature should not be taken from a radio station, a sign displaying the
temperature, etc. A temperature measuring tool such as a thermometer should be used. Some temperature measuring tools may be within 5 degrees of
the actual temperature. Make sure to consult the manufacturer for the accuracy of the tool. This comparison can make the mirror seem off by 5-10
degrees
 of the actual temperature when it is not.

TEST

Initial Inspection and Diagnostic Overview|Page 10393 > < Initial Inspection and Diagnostic Overview|Page 10391