01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Chevrolet Corsica V6-3100 3.1L VIN M SFI (1996)01 · Relays and Modules
01 · Diagnostics

Multi-Function Alarm Module - Diagnostics Revision

Make
Chevrolet
Model
Corsica
Engine
V6-3100 3.1L VIN M SFI
Year
1996
Section
Alarm Module, (Vehicle Antitheft) › Technical Service Bulletins › Multi-Function Alarm Module - Diagnostics Revision
Relays and ModulesMulti-Function Alarm Module - Diagnostics Revision
Multi-Function Alarm Module - Diagnostics Revision – Chevrolet Corsica V6-3100 3.1L VIN M SFI (1996)

Alarm Module: Technical Service Bulletins
Multi-Function Alarm Module - Diagnostics Revision

File In Section: 8 - Chassis/Body Electrical 

Bulletin No.: 53-81-25A

Date: October, 1995

SERVICE MANUAL UPDATE

Subject: 
Section 8A - Revised Multi-function Alarm Module Diagnostics

Models: 
1995 Buick Skylark
1995-96 Chevrolet Beretta, Corsica
1995 Oldsmobile Achieva
1995 Pontiac Grand Am

This bulletin is being revised to correct text in Paragraph 1. Please discard Corporate Bulletin Number 53-81-25 (Section 8 - Chassis/Body Electrical).

When placing the Multi-function Alarm Module in the Power Output Diagnostic Mode, 4 failure modes can be set. The 1995 and 1996 Service
information does not list the fourth failure mode and should be updated as follows.

When the Multi-function Alarm Module chimes 4 times every 3 seconds during the Power Output Diagnostic Mode, a failure of the seat belt door
retractor solenoids has been detected and the appropriate diagnostic chart in Section 8A-146 should be referred to. Once the necessary repairs have been
performed, reset the Multi-function Alarm Module by removing fuse 11 or the Alarm fuse as noted in Section 8A-76.

The procedure to place the Multi-function Alarm Module in the Power Output Diagnostic Mode is listed in Section 8A-76 but should also be added to
Section 8A-146. The procedure is as follows:

1.

Close front doors.

2.

Set park brake.

3.

Turn interior lights on using panel dimmer switch.

4.

Turn ignition switch to "Run" and before 15 seconds elapse, perform the following steps:

a.

Open RH front door.

b.

Cycle headlamp switch from "Park" to "Off" 3 times.