Audible Warning Device Control Module: Description and Operation

The Multi-function Alarm Module sounds the Lights-on chime when the following three conditions are met:

^

Battery voltage at Conn C1 terminal "D" indicates that the Park or Headlights are on.

^

0 volts at Conn C1 terminal "M" indicates that the Ignition Switch is in "OFF," "ACCY," or "LOCK."

^

Ground at Conn C1 terminal "H" indicates that the LH door is open.

Relays and Modules - Lighting and Horns > < Diagram Information and Instructions|Page 144