8. Connect the heater outlet hose (2) to the heater outlet pipe.
9. Position the heater outlet hose clamp (1) over the heater outlet pipe connection.

10. Connect the electrical connector to the EGR valve.
11. Connect the electrical connector to the EVAP canister purge solenoid.
12. Connect the EVAP pipe to the EVAP canister purge solenoid. Refer to Plastic Collar Quick Connect Fitting Service   .

13. Reposition the MAP sensor.
14. Install the MAP sensor bracket (2) and bolt (3).

Tighten the bolt to 10 N.m (89 lb in).

15. Install the air cleaner air intake duct. Refer to Air Cleaner Inlet Duct Replacement   .
16. Fill the cooling system. Refer to Cooling System Draining and Filling (LNJ Static Fill)  (See: Service and Repair)Cooling System Draining and

Filling (LNJ GE 47716 Fill)  (See: Service and Repair)Cooling System Draining and Filling (LY7 Static Fill)  (See: Service and Repair)Cooling
System Draining and Filling (LY7 GE 47716 Fill)  (See: Service and Repair) .

17. Install the injector sight shield. Refer to Fuel Injector Sight Shield Replacement  (See: Powertrain Management/Fuel Delivery and Air

Induction/Fuel Injector/Service and Repair/Removal and Replacement/Fuel Injector Sight Shield Replacement) .