chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 9489 > < Diagram Information and Instructions|Page 9487
Page 5
background image

IMPORTANT:  The J 39200 must be used in order to perform the following procedure since the J 39200 can monitor current, resistance or voltage
while recording the minimum (MIN), and maximum (MAX) values measured.

1. Connect the J 39200 to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other. Refer to 

Troubleshooting with a Digital Multimeter for information on connecting the J 39200 to the circuit.  See: General Electrical Diagnostic
Procedures/Troubleshooting Tools/Digital Multimeter

2. Set the rotary dial of the J 39200 to the V (AC) or V (DC) position.
3. Press the range button of the J 39200 in order to select the desired voltage range.
4. Press the MIN MAX button of the J 39200. The J 39200 displays 100 ms RECORD and emits an audible tone (beep).

IMPORTANT:  The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.

5. Simulate the condition that is potentially causing the intermittent connection, either by wiggling the connections or the wiring, test driving, or

performing other operations.

6. Listen for the audible Min Max Alert which indicates that a new minimum or maximum value has been recorded.
7. Press the MIN MAX button once in order to display the MAX value and note the value.
8. Press the MIN MAX button again in order to display the MIN value and note the value.
9. Determine the difference between the MIN and MAX values.

^

If the variation between the recorded MIN and MAX voltage values is 1 volt or greater an intermittent open or high resistance condition exists.
Repair the condition as necessary.

^

If the variation between the recorded MIN and MAX voltage values is less than 1 volt an intermittent open or high resistance condition does
not exist.

Digital Multimeter

NOTE:  Refer to Test Probe Notice in Cautions and Notices.

IMPORTANT:  Circuits which include any solid state control modules, such as the PCM, should only be tested with a 10 megohm or higher impedance
digital multimeter such as the J 39200.

The J 39200 Instruction Manual is a good source of information and should be read thoroughly upon receipt of the DMM as well as kept on hand for
future reference.

A DMM should be used instead of a test lamp in order to test for voltage in high impedance circuits. While a test lamp shows whether voltage is present,
a DMM indicates how much voltage is present.

The ohmmeter function on a DMM shows how much resistance exists between two points along a circuit. Low resistance in a circuit means good
continuity.

IMPORTANT:  Disconnect the power feed from the suspect circuit when measuring resistance with a DMM. This prevents incorrect readings. DMMs
apply such a small voltage to measure resistance that the presence of voltages can upset a resistance reading.

Diodes and solid state components in a circuit can cause a DMM to display a false reading. To find out if a component is affecting a measurement take a
reading once, then reverse the leads and take a second reading. If the readings differ the solid state component is affecting the measurement. 

Following are examples of the various methods of connecting the DMM to the circuit to be tested:

^

Backprobe both ends of the connector and either hold the leads in place while manipulating the connector or tape the leads to the harness for
continuous monitoring while you perform other operations or test driving. Refer to Probing Electrical Connectors.  See: General Electrical
Diagnostic Procedures/Troubleshooting Tools/Probing Electrical Connectors

^

Disconnect the harness at both ends of the suspected circuit where it connects either to a component or to other harnesses.

^

If the system that is being diagnosed has a specified pinout or breakout box, it may be used in order to simplify connecting the DMM to the circuit
or for testing multiple circuits quickly.

Short Finder

The J 8681-A can locate hidden shorts to ground. The short finder creates a pulsing magnetic field in the shorted circuit and shows the location of the
short through the body trim or sheet metal.

Test Lamp

NOTE:  Refer to Test Probe Notice in Cautions and Notices.

A test lamp can simply and quickly test a low impedance circuit for voltage.

The J 34142-B Test Lamp is Micro-Pack compatible and comprised of a 12 volt light bulb with an attached pair of leads.

To properly operate this tool use the following procedure.

1. Attach one lead to ground.

Diagram Information and Instructions|Page 9489 > < Diagram Information and Instructions|Page 9487