Express 2500 V8-4.8L (2007)
Housing Assembly HVAC: Service and Repair
Air Conditioning (A/C) Evaporator and Blower Module Assembly Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
2. Remove the coolant recovery reservoir.
3. Disconnect the low pressure sensor electrical connector (2).
4. Disconnect the blower motor assembly electrical connector.