chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Valve Rocker Arm Upper Cover Replacement - Left Side|Page 2525 > < Valve Rocker Arm Upper Cover Replacement - Left Side|Page 2523
Page 3
background image

Charging/Battery/Battery Cable/Negative/Service and Repair/Battery Negative Cable Disconnection and Connection).

3. Remove the auxiliary generator, if equipped. Refer to Auxiliary Generator Replacement (KD9)   (See: Starting and Charging/Charging

System/Alternator/Service and Repair/Auxiliary Generator Replacement  (KD9)).

4. Remove the glow plug control module. Refer to Glow Plug Control Module Replacement   (See: Powertrain Management/Glow Plug

System/Glow Plug Control Module/Service and Repair/Glow Plug Control Module Replacement).

5. Remove the glow plug module bracket bolts (1) and bracket.

Caution:  Label all the injector electrical connectors before the connectors are removed in order to prevent reconnecting to the wrong injector.
Failure to properly connect the injectors in the correct sequence will cause severe engine damage.

6. Disconnect the engine harness electrical connectors from the fuel injectors.

7. Remove the engine wiring harness bracket bolt (1).

Valve Rocker Arm Upper Cover Replacement - Left Side|Page 2525 > < Valve Rocker Arm Upper Cover Replacement - Left Side|Page 2523