chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Defroster Valve Actuator Replacement|Page 12653 > < Defroster Valve Actuator Replacement|Page 12651
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Air Inlet Valve Actuator Replacement

Air Inlet Valve Actuator Replacement

Special Tools

J 39400-A  Electronic Halogen Leak Detector

Removal Procedure

1. Remove the battery. Refer to Battery Replacement (Primary)   (See: Starting and Charging/Battery/Service and Repair/Removal and Replacement

).

2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging   (See: Service and Repair/Refrigerant Recovery and

Recharging).

3. Disconnect the low pressure sensor electrical connector.
4. Disconnect the blower motor electrical connector.
5. Disconnect the blower motor resistor assembly electrical connector.

6. Remove the evaporator outlet hose retaining nuts (4, 5).

7. Remove the retaining nut (3) from the evaporator inlet tube (5).
8. Remove the evaporator inlet tube from the evaporator and position aside.
9. Remove the sealing washers.

Defroster Valve Actuator Replacement|Page 12653 > < Defroster Valve Actuator Replacement|Page 12651