chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Evaporator Tube Replacement|Page 7534 > < Evaporator Tube Replacement|Page 7532
Page 1
background image

Hose/Line HVAC: Service and Repair
Suction Hose Replacement

SUCTION HOSE REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the coolant recovery reservoir.
3. Remove the suction line nut (1) from the accumulator.
4. Remove the rear suction line nut (2) if equipped with rear air.
5. Raise the vehicle. Refer to Vehicle Lifting.
6. Remove the suction line bolt from the compressor.
7. Remove the suction line from the vehicle.

INSTALLATION PROCEDURE

1. Install the suction line into the vehicle.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the suction line bolt to the compressor.

Tighten
Tighten the bolt to 35 N.m (26 lb ft).

Evaporator Tube Replacement|Page 7534 > < Evaporator Tube Replacement|Page 7532