chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

4L60-E Automatic Transmission|Page 7588 > < 4L60-E Automatic Transmission|Page 7586
Page 1
background image

Transmission Cooler: Service and Repair
4L80-E Automatic Transmission

^

Tools Required 
-

J35944-A Cooler Flushing Tool

-

J35944-20 Biodegradable Flushing Solution

PREPARATION 

Flush the transmission oil cooler whenever the transmission is removed for service. It is essential to flush the oil cooler after transmission installation,
after a major overhaul, if oil contamination is suspected, or in any case of pump or torque converter replacement.
Perform the flush procedure after the overhaul or replacement assembly has been reinstalled in the vehicle to ensure the complete transmission system
service.
1. Do not reconnect the oil cooler lines after installing the overhauled or service replacement transmission.
2. Remove the fill cap on J35944-A.
3. Fill the can with 0.6L (20 - 21 ounces) of flushing solution. Do not overfill the tool or the tool will need to be recharged with air before the

backflush. Follow the manufacturer's suggested procedures for proper handling of the solution.

NOTICE:  Do not substitute with any other solution. The flushing tool is designed to use only this concentrate. Use of any other solution can
result in damage to. the tool, cooler components, or improper flushing of the cooler.

4. Secure the fill cap.
5. Pressurize the flusher can with shop air to 550 - 700 kPa (80 - 100 psi).

CAUTION:  Air supply must be equipped with a water and oil filter. This air supply must not exceed 825 kPa (120 psi). Excess air pressure may
rupture the flushing cooler, causing personal injury.

6. Connect the discharge hose to the transmission end of the oil cooler lines that goes to the top fitting at the radiator.
7. Clip the discharge hose onto the oil drain container.
8. Secure the flushing tool to the undercarriage of the vehicle with the hook provided.
9. Connect the hose from the flushing tool to the remaining oil cooler lines.

10. Switch the water valve on the tool to the OFF position.
11. Connect the water hose from the water supply to the tool.
12. Turn on the water supply at the faucet.

INITIAL FLUSH 

CAUTION:  If water does not flow through the oil cooler (system is completely plugged), do not continue flushing procedure. Turn the water off
immediately and inspect the lines and cooler for restrictions and repair, or personal injury could result.

1. Switch the water valve on the tool to the ON position.
2. Allow the water to flow through the oil cooler for 10 seconds in order to remove the supply of transmission fluid in the system.
3. Switch the water valve on the tool to the OFF position.
4. Clip the discharge hose onto a 5 gallon pail.
5. Secure a lid on the pail or position a shop towel over the end of the discharge hose in order to prevent a splash. The discharge will foam vigorously

when the solution is introduced in the water stream.

6. Switch the water valve on the tool to the ON position.
7. Depress the trigger to mix the flushing solution in the water flow. Use the bale clip provided on the handle to hold the trigger down.
8. Attach the air supply to the air valve located on the plumbing of the tool for 3-5 seconds at the end of every 15-20 second interval, in order to

create a surging action.

9. Flush the oil cooler with water and solution for 2 minutes.

10. Release the trigger.
11. Switch the water valve on the tool to the OFF position.
12. Disconnect both hoses from the oil cooler lines.

BACKFLUSH 

1. Connect the hoses to the oil cooler lines in the opposite order from the initial flush procedures to perform a backflush.
2. Switch the water valve on the tool to the ON position.
3. Depress the trigger to mix the flushing solution in the water flow. Use the bale clip provided on the handle to hold the trigger down.
4. Attach the air supply to the air valve located on the plumbing of the tool for 3-5 seconds at the end of every 15-20 second interval, in order to

create a surging action.

5. Flush the oil cooler with water and solution for 2 minutes.
6. Release the trigger and allow only water to rinse the oil cooler for 1 minute.
7. Switch the water valve on the tool to the OFF position.
8. Turn the water supply off at the faucet.
9. Attach the air supply to the air valve located on the plumbing of the tool.

10. Dry the system out with air for at least 2 minutes.

4L60-E Automatic Transmission|Page 7588 > < 4L60-E Automatic Transmission|Page 7586