Express 4500 V8-6.0L (2010)
Housing Assembly HVAC: Service and Repair
Air Conditioning (A/C) Evaporator and Blower Module Assembly Replacement
Air Conditioning (A/C) Evaporator and Blower Module Assembly Replacement
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging (See: Service and Repair/Refrigerant Recovery and
Recharging).
2. Remove the coolant recovery reservoir. Refer to Coolant Recovery Reservoir Replacement (See: Engine, Cooling and Exhaust/Cooling
System/Coolant Reservoir/Service and Repair/Coolant Recovery Reservoir Replacement).
3. Disconnect the low pressure sensor electrical connector (2).
4. Disconnect the blower motor assembly electrical connector.