chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Symptoms - Power Outlets|Page 8128 > < Symptoms - Power Outlets
Page 1
background image

Auxiliary Power Outlet: Testing and Inspection
Power Outlet Receptacle Inoperative (120 VAC)

Power Outlet Receptacle Malfunction

Diagnostic Instructions

*

Perform the Diagnostic System Check - Vehicle   (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System
Check - Vehicle) prior to using this diagnostic procedure.

*

Review Strategy Based Diagnosis   (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an
overview of the diagnostic approach.

*

Diagnostic Procedure Instructions   (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure Instructions
)provides an overview of each diagnostic category.

Diagnostic Fault Information

Circuit/System Description

The accessory power receptacles and cigarette lighter receptacle are supplied B+ all the time.

Reference Information
Schematic Reference

Cigar Lighter/Power Outlet Schematics   (See: Diagrams/Electrical Diagrams)
Connector End View Reference

Component Connector End Views   (See: Diagrams/Connector Views/Connector End Views By Name)
Description and Operation

Power Outlets Description and Operation   (See: Description and Operation)
Electrical Information Reference

*

Circuit Testing   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit
Testing/Circuit Testing)

*

Connector Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector
Repairs/Connector Repairs)

*

Testing for Intermittent Conditions and Poor Connections   (See: Testing and Inspection/Component Tests and General Diagnostics/General
Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

*

Wiring Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring
Repairs/Wiring Repairs)

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the appropriate accessory power receptacle or cigarette lighter receptacle.
2. Test for less than 5 ohm between the ground circuit terminal C and ground.

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

3. Verify that a test lamp illuminate between the B+ circuit terminal A and ground.

‹› If test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

4. If the circuits test normal, test or replace the accessory power receptacle.

Repair Instructions

Perform the Diagnostic Repair Verification   (See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble
Code Tests and Associated Procedures/Verification Tests and Procedures) after completing the diagnostic procedure.

Symptoms - Power Outlets|Page 8128 > < Symptoms - Power Outlets