HHR L4-2.4L (2010)
Harmonic Balancer - Crankshaft Pulley: Service and Repair
Crankshaft Balancer Replacement
Special Tools
*
J 38122-A Harmonic Balancer Holder
*
J 45059 Angle Meter
Removal Procedure
1. Remove the drive belt. Refer to Drive Belt Replacement (See: Drive Belts, Mounts, Brackets and Accessories/Drive Belt/Service and Repair).
2. Use J 38122-A to prevent the crankshaft from rotating while loosening the crankshaft balancer bolt.
3. Remove and discard the crankshaft balancer bolt.
4. Remove the crankshaft balancer.
Installation Procedure