chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Restraint Systems > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 10409
Page 1
background image

Service Port HVAC: Service and Repair

SERVICE PORTS REPLACEMENT

TOOLS REQUIRED

J 39037Charge Valve Octagon Socket

REMOVAL PROCEDURE

1. Remove the service port cap.
2. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.

3. Use the J 39037 to remove the service port.

INSTALLATION PROCEDURE

1. Replace the O-ring.

2. Install the service port valve.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the valve to 11 N.m (98 lb in).

3. Evacuate and charge the system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the A/C service port. Refer to Leak Testing.
5. Install the service port cap.

Restraint Systems > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 10409