Page 6
background image

Notice:  Refer to Fastener Notice   .

5. Install the valve body bolts (374-381, 384).

*

Tighten the M6 X 1.0 X 20 bolt (381) to 8 N.m (70 lb in).

*

Tighten the M6 X 1.0 X 30 bolt (376) to 12 N.m (106 lb in).

*

Tighten the M6 X 1.0 X 45 bolt (377) to 12 N.m (106 lb in).

*

Tighten the M6 X 1.0 X 55 bolt (378) to 12 N.m (106 lb in).

*

Tighten the M6 X 1.0 X 60 bolt (375) to 12 N.m (106 lb in).

*

Tighten the M6 X 1.0 X 65 bolt (374) to 12 N.m (106 lb in).

*

Tighten the M6 X 1.0 X 85 bolt (384) to 12 N.m (106 lb in).

*

Tighten the M6 X 1.0 X 95 bolt (379) to 16 N.m (11 lb ft).

*

Tighten the M8 X 1.25 X 90 bolt (380) to 25 N.m (18 lb ft).

6. Install the oil pump. Refer to Oil Pump Replacement  (See: Fluid Pump/Service and Repair) .
7. Install the case side cover. Refer to Control Valve Body Cover Replacement  (See: Control Valve Body Cover Replacement) .

Important:  It is recommended that transmission adaptive pressure (TAP) information be reset.

Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will need to
relearn TAP values. Transmission performance may be affected as new TAP values are learned.

8. Reset the TAP values. Refer to Transmission Adaptive Functions  (See: Description and Operation/Transmission Adaptive Functions) .