chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

SIR Disabling and Enabling Zones|Page 2725 > < SIR Disabling and Enabling Zones|Page 2723
Page 2
background image

9. Disconnect the seat belt pretensioner-LF connector from the vehicle harness connector.

10. Remove the garnish molding from the upper lock pillar.
11. Remove the CPA from the roof rail module-left connector.
12. Disconnect the roof rail module-left connector from the vehicle harness connector.

13. Remove the LH door trim panel (2).

14. Remove the connector position assurance (CPA) (3) from the SIS-Left connector (4).
15. Remove the SIS-Left connector (4) from the SIS (2).

ENABLING PROCEDURE

1. Remove the key from the ignition switch.
2. To enable the SIS-Left go to step 3. To enable the roof rail module-left go to step 7, and to enable the seat belt pretensioner-LF go to step 9.

3. Install the SIS-Left connector (4) to the SIS (2).
4. Install the CPA (3) to the SIS-Left connector (4).

SIR Disabling and Enabling Zones|Page 2725 > < SIR Disabling and Enabling Zones|Page 2723