chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Refrigerant Oil|Capacity Specifications|Page 7714 > < Refrigerant Filter|Service and Repair|Page 7709
Page 1
background image

Refrigerant Oil: Capacity Specifications

Abrupt Refrigerant Loss .............................................................................................................................................................................  60 ml (2.0 oz) (1)
 
Compressor Replacement
 
The service compressor for the LY7 engine is precharged with 150 ml (5 oz) of PAG oil. 
The service compressor for the LAT, LE5, LZ4 and LZE engines are precharged with 74 ml (2.5 oz) of PAG oil. 
 
Condenser Replacement .............................................................................................................................................................................  30 ml (1.0 oz) (2)
 
Evaporator Replacement ............................................................................................................................................................................  45 ml (1.5 oz) (2)
 
Total System PAG Oil Capacity ....................................................................................................................................................................  150 ml (5.0 oz)

1)Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed
off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the
particular component.

(2)If more than the specified amount of PAG oil was drained from a component, add the equal amount of oil drained.
 

Refrigerant Oil|Capacity Specifications|Page 7714 > < Refrigerant Filter|Service and Repair|Page 7709