chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

HVAC System - Automatic|Page 7309 > < HVAC System - Automatic|Page 7307
Page 3
background image

5. Remove the mode actuator.

INSTALLATION PROCEDURE

1. Install the mode actuator.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the mode actuator screws.

Tighten
Tighten the screws to 1.5 N.m (13 lb in).

3. Install the mode actuator wire harness connector.
4. Close I/P compartment door.
5. Install the fuse labeled HVAC CTRL (BATT).

Recirculation Actuator Replacement

RECIRCULATION ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the fuse labeled HVAC CTRL (BATT).
2. Remove the right closeout panel.
3. Remove the communication interface module.
4. Remove the OnStar module bracket.

HVAC System - Automatic|Page 7309 > < HVAC System - Automatic|Page 7307