chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Cleaner Outlet Duct Replacement|Page 1205 > < Air Cleaner Outlet Duct Replacement
Page 2
background image

Installation Procedure

1. Position and install the air cleaner outlet duct to the MAF/IAT sensor and the throttle body.

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution).

2. Install the air cleaner outlet duct bolt (2) and tighten to 10 Nm (89 lb in).
3. Tighten the air cleaner outlet duct clamps (1, 3) at the MAF/IAT sensor and throttle body to 4 Nm (35 lb in).

4. Position the PCV tube.
5. Connect the PCV fresh air tube (1) quick connect fitting to the air cleaner outlet duct.
6. Install the fuel injector sight shield. Refer to Fuel Injector Sight Shield Replacement   (See: Powertrain Management/Fuel Delivery and Air

Induction/Fuel Injector/Service and Repair/Fuel Injector Sight Shield Replacement).

Air Cleaner Outlet Duct Replacement|Page 1205 > < Air Cleaner Outlet Duct Replacement