chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Service and Repair|Page 14061
Page 9
background image

Important:  Do not allow the upper bracket to twist when tightening the radiator mounting bolts or vibration may result.

26. Install both upper radiator support bracket bolts.

Tighten the bolt to 10 N.m (89 lb in).

27. Install the right headlamp.
28. Install the left headlamp.
29. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
30. Leak test the fittings using the J 39400-A.

Control Assembly, HVAC > < Condenser HVAC|Service and Repair|Page 14061