Fuel Tank Pressure Sensor: Testing and Inspection
EVAP Tank Pressure Control Solenoid Valve Inspection
EVAP Tank Pressure Control Solenoid Valve Inspection
Tools Required
J 39200 Digital Multimeter
1. Disconnect the EVAP tank pressure control solenoid valve electrical connector.
2. Measure the resistance between the electrical terminals of the EVAP tank pressure control solenoid valve (2) with the DMM (1). The resistance
should be 28 to 36 ohms at 20°C (68°F).
3. Replace the EVAP tank pressure control solenoid valve if the resistance is not 28 to 36 ohms at 20°C (68°F). Proceed to step 3 if the resistance is
within the specification. Refer to EVAP Tank Pressure Control Solenoid Valve Replace Replacement.
4. Disconnect the EVAP tank pressure control solenoid valve vacuum hoses from the intake manifold and from the Tank Pressure Control valve
vacuum pipe.
5. Blow air into the EVAP tank pressure control solenoid valve vacuum hose that was disconnected from the vacuum pipe. Air should not pass
through the EVAP tank pressure control solenoid valve and exit from the intake manifold hose.