chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Brake Warning Indicator > < Symptom Related Diagnostic Procedures|Page 12283
Page 1
background image

Audible Warning Device: Component Tests and General Diagnostics

SAFETY BELT WARNING BUZZER

With the Ignition Switch in START or RUN, voltage is supplied to the Seat Belt & Ignition Key & Lamps Alarm through the GAUGES Fuse 4
and the PNK (39) wire. When the Ignition Switch is first turned to START or RUN. voltage from the Seat Belt & Ignition Key & Lamps Alarm is
supplied to the Fasten Safety Belt Indicator in the Instrument Cluster through the YEL (237) wire. The indicator stays lit for about 5 seconds.

If the driver's safety belt is not buckled, a ground is applied to the Seat Belt & Ignition Key & Lamps Alarm through the BLK/WHT (238) wire
from the Safety Belt Retractor Switch. The chime or buzzer will sound for about five seconds.

KEY-IN WARNING BUZZER

Voltage is supplied at all times to the Seat Belt & Ignition Key & Lamps Alarm through the STOP HAZ Fuse 1 and the ORN (140) wire. With the
key in the Ignition Switch and the Ignition Switch in ACC, Lock, or Off, the chime or buzzer will sound if the left door is open.

With the door open, the LH Front Side Door Jamb Switch closes to ground. This provides a ground to the Seat Belt & Ignition Key & Lamps
Alarm through the TAN (159) wire, the Ignition Key Alarm Switch, and the LT GRN (80) wire. The chime or buzzer will sound as long as the
door is open and the key is in the Ignition Switch.

LAMPS-ON WARNING BUZZER

When the Light Switch is in Head or Park, and the Panel Dimmer Switch is not at the dimmest setting, voltage is supplied through the ILLUM
Fuse 21 to the Seat Belt & Ignition Key & Lamps Alarm through the GRY (8) wire. With the Panel Dimmer Switch at its dimmest setting, the
current to the Seat Belt & Ignition Key & Lamps Alarm may not be enough to be sensed by the module. When the Ignition Switch is turned to
RUN or START, voltage is supplied through GAUGES Fuse 4 to the alarm module through the PNK (39) wire. These two voltages are sensed and
the alarm is not sounded.

When the Ignition Switch is turned to Lock, Off, or ACC, GAUGES Fuse 4 loses voltage. The Seat Belt & Ignition Key & Lamps Alarm senses
the change. If voltage is still available from ILLUM Fuse 21, voltage from STOP HAZ Fuse 1 is supplied to sound the alarm through the ORN
(140) wire. The alarm can be turned off by turning the Headlamp Switch off. The alarm module no longer senses voltage from the Headlamp
Switch, so the alarm does not sound.

Brake Warning Indicator > < Symptom Related Diagnostic Procedures|Page 12283