chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Technician Safety Information|Page 9880 > < Technician Safety Information|Page 9878
Page 1
background image

High Pressure Safety Valve HVAC: Description and Operation

The compressor is equipped with a pressure relief valve as a safety factor. Under certain conditions, the refrigerant on the discharge side may exceed the
designed operating pressure. Exceeding this pressure limit may cause refrigerant loss. To prevent refrigerant loss or system damage, the valve opens
automatically at approximately 3036 kPa (440 psi). When the valve opens, current to the compressor clutch is interrupted. Any condition that causes the
valve to open should be corrected.

Technician Safety Information|Page 9880 > < Technician Safety Information|Page 9878