chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

HVAC System - Automatic|Page 14146 > < HVAC System - Automatic|Page 14144
Page 3
background image

6. Remove the mode actuator mounting screws from the HVAC module.
7. Remove the mode actuator as an assembly with the actuator cam.

INSTALLATION PROCEDURE

1. Install the mode actuator as an assembly with the actuator cam.

-

Line up the heater/defroster valve lever with the mode actuator cam slot.

-

Line up the A/C valve lever with the mode actuator cam.

2. Install the mode actuator mounting screws to the HVAC module.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the screws to 1.6 N.m (14 lb in).

3. Connect the electrical connection at the mode actuator (10).

4. Install the center console duct.
5. Install the screws to the center console duct.

Tighten the screws to 1.6 N.m (14 lb in).

6. Install the center console.
7. Install the floor air outlet duct extension (1) to the floor air duct (2).

Mode Actuator (Without RPO Code D07)

HVAC System - Automatic|Page 14146 > < HVAC System - Automatic|Page 14144