Canister Vent Valve: Service and Repair
EVAP Canister Vent Solenoid Valve Replacement 2

EVAPORATIVE EMISSION (EVAP) CANISTER VENT SOLENOID VALVE REPLACEMENT

REMOVAL PROCEDURE

IMPORTANT:  Clean all evaporative emission (EVAP) pipe connections and surrounding areas before disconnecting the pipe in order to avoid
possible EVAP system contamination.

1. Remove the fuel tank.
2. Disconnect the EVAP vent valve electrical connector (1).

3. Open the pipe retaining clips.
4. Remove the EVAP vent valve bracket bolt.
5. Remove the EVAP pipe from the retaining clips.
6. Remove the EVAP vent valve with pipe.

INSTALLATION PROCEDURE