Information Bus: Testing and Inspection
Scan Tool Does Not Communicate with High Speed GMLAN Device

SCAN TOOL DOES NOT COMMUNICATE WITH HIGH SPEED GMLAN DEVICE

CIRCUIT DESCRIPTION

Modules connected to the high speed GMLAN serial data circuits monitor for serial data communications on the high speed GMLAN network during
normal vehicle operation. Operating information and commands are exchanged among the modules.

The scan tool communicates with the following modules via the high speed GMLAN:
-

Energy Storage Control Module (ESCM)

-

Starter/Generator Control Module (SGCM)

-

Electro-Hydraulic Power Steering (EHPS) Module

DIAGNOSTIC AIDS

IMPORTANT:  The tool communication with the modules connected only to high speed GMLAN data link requires the use of the CANdi module.
Due to configuration of this vehicle, they may be communication DTCs set against modules that are able to communicate with the scan tool.

The following conditions may cause a total loss of high speed GMLAN data communication:
-

A short between high speed GMLAN (+) and high speed GMLAN (-) circuits

-

Any of the high speed GMLAN serial data circuits shorted to ground or voltage

-

A module internal malfunction that causes a short to voltage or ground on the high speed GMLAN circuits