background image

Braking Sensor/Switch: Adjustments

Brake Pedal Position Sensor Calibration 

Calibration Criteria 

The brake pedal position (BPP) sensor receives a low reference signal and a 5 volt reference signal from the electro hydraulic power steering (EHPS)
module. Whenever the brake pedal is pressed, the brake pedal position sensor applies a variable voltage signal to the EHPS module through the BPP
sensor signal circuit. Brake pedal position sensor calibration must be performed after the brake pedal position sensor or EHPS system have been
serviced. The calibration procedure will set brake pedal position sensor home value. This value is used by the EHPS module to determine the brake
pedal position and the brake pedal rate. These two outputs are provided to the hybrid control module (HCM) via GMLAN.

Calibration Procedure 

1. Install a scan tool.
2. Turn ON the ignition, with the engine OFF.

3. Important:  

Make sure the brake pedal is not pressed before sending the BPP sensor calibration command.

Navigate to the Special Functions screen on the scan tool and select BPP Sensor Calibration in order to perform the brake pedal position sensor
calibration.