Silverado Classic 1500 4WD V8-5.3L Hybrid (2007)
2. Install the power cable nuts (1) to battery 1 and battery 2.
Tighten the nuts to 10 N.m (89 lb in).
3. Install the generator battery carrier intermediate cover.
Battery to Battery Positive to Negative Cable Replacement - Battery 2 to Battery 3 (5.3L Engine
w/RPO HP2)
Battery to Battery Positive to Negative Cable Replacement - Battery 2 to Battery 3 (5.3L Engine w/RPO HP2)
Caution: To help avoid personal injury, disable the 36V system anytime you perform service work on or around the generator battery carrier.
The 36V system will still be active after you have disabled the generator battery carrier.
Caution: To help avoid personal injury, always disconnect the 36V generator battery carrier before doing any work to the generator battery
carrier system. To disconnect the generator battery carrier, turn the engine off and turn OFF the service disconnect switch, which is located on
the passenger side of the generator battery carrier.
Removal Procedure
1. Remove the generator battery carrier intermediate cover.
2. Cut the tie straps (1) securing the power cable to the generator battery carrier.
3. Remove the power cable nuts (3) from battery 2 and battery 3.
4. Remove the power cable (2) from battery 2 and battery 3.
Installation Procedure
1. Install the power cable (2) battery 2 and battery 3.