Silverado Classic 3500 4WD V8-66L DSL Turbo (2007) Throttle Position Sensor Diagrams
6. Gently pry the plastic terminal retainer down and carefully pull the terminal out of the connector. Always remember never use force when pulling a
terminal out of a connector. If the terminal is difficult to remove, repeat the entire procedure.
TERMINAL REPAIR PROCEDURE
Use the appropriate terminal and follow the instructions in the J-38125.
Yazaki Connectors (16-Way)
YAZAKI CONNECTORS (16-WAY)
TOOLS REQUIRED
J-38125 Terminal Repair Kit
REMOVAL PROCEDURE
1. While depressing the lock, pull the two connector halves apart.