1. Remove the air cleaner.
2. Disconnect the drive motor generator control module assembly connector (1).

Caution:  High Voltage (HV) cables should never be removed from the mounting block. Removal of the individual HV cable from the
mounting block may result in HV cable and/or component damage from improper:

*

Cable sealing

*

Electrical shielding

*

Terminal position assurance

Drain the power electronics cooling system. Refer to Generator Control Module Cooling System Draining and Filling.

Caution:  Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic
circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.