Starter Solenoid: Testing and Inspection

Testing and Inspection 

1.

Measure the starter solenoid pull-in coil resistance between terminal S (2) and terminal M using the J 39200. If the resistance is greater than 5.0
ohms
, the pull-in coil is open. Replace the starter solenoid.

2.

Measure the starter solenoid hold-in coil resistance between terminal S (3) and the solenoid case (1) using the J 39200. If the resistance is greater
than 5.0 ohms, the hold-in coil is open. Replace the starter solenoid.

For additional diagnostic procedures:

  
  See: Testing and Inspection

Power and Ground Distribution > < Starter Solenoid|Specifications