Tracker 4WD L4-1.6L VIN 6 (1998)
3. Place the armature onto a pair of V-blocks (1). Measure the commutator run-out using a J 8001 with a J 26900-la If the run-out exceeds the
maximum, replace the armature.
STANDARD COMMUTATOR RUN-OUT
0.05 mm (0.002 in) or less
MAXIMUM COMMUTATOR RUN-OUT
0.40 mm (0.016 in)
4. Measure the outside diameter of the commutator using a J 26900-5. If the outside diameter is less than the minimum, replace the armature (1).
STANDARD COMMUTATOR DIAMETER
29.4 mm (1.157 in)
MINIMUM COMMUTATOR DIAMETER
28.8 mm (1.134 in)