chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Housing Assembly HVAC > < High Pressure Safety Valve HVAC|Specifications
Page 1
background image

High Pressure Safety Valve HVAC: Service and Repair

COMPRESSOR PRESSURE RELIEF VALVE REPLACEMENT

REMOVAL PROCEDURE

IMPORTANT:

^

Discharge and recover the A/C system refrigerant, and remove the compressor from the vehicle, before performing compressor repairs and
procedures.

^

During service of the compressor, prevent dirt and other foreign material from getting on the compressor parts and into the system. Clean tools and
a clean work area are essential for proper service. Keep the compressor and the parts clean at all times.

^

Clean all parts with a suitable solvent and air dry the parts prior to reassembly.

^

Use only lint-free cloths to wipe the parts.

^

Drain, measure and discard the remaining refrigerant oil when the compressor is removed from the vehicle. Add the same amount of new oil when
the repairs are complete.

1. If there is any sign of oil leakage, replace the pressure relief valve.
2. Discharge and recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
3. Remove the pressure relief valve.
4. Remove the pressure relief valve and the O-ring seal from the compressor.
5. Discard the O-ring.

INSTALLATION PROCEDURE

1. Lubricate the new O-ring with mineral base 525 Viscosity refrigerant oil.
2. Install the O-ring to the pressure relief valve. 

NOTE:  Refer to Fastener Notice in Cautions and Notices.

3. Install the pressure relief valve to the compressor.

Tighten
Tighten the pressure relief valve to 12-18 N.m (8.7-13 lb ft).

4. Evacuate and recharge the air conditioning system. Refer to Refrigerant Recovery and Recharging.
5. Operate the A/C system and test for refrigerant leaks. Refer to Leak Testing.

Housing Assembly HVAC > < High Pressure Safety Valve HVAC|Specifications