Tracker 4WD L4-2.0L VIN C (1999)
Positive Crankcase Ventilation Valve: Service and Repair
Positive Crankcase Ventilation Valve Replacement
REMOVAL PROCEDURE
1. Loosen the positive crankcase ventilation (PCV) valve hose clamp (1).
2. Remove the intake manifold vacuum hose (3) from the PCV valve.
3. Remove the PCV valve from the valve cover grommet (2).
INSTALLATION PROCEDURE
1. Install the PCV valve into the valve cover grommet (2).
2. Connect the intake manifold vacuum hose (3) to the PCV valve.
3. Secure the PCV valve with the hose clamp (1).