Tighten the generator upper bracket bolts to 45 N.m (32 lb ft).

IMPORTANT:  Do not torque the bolts until the drive belt tension is correct.

3. Install the adjusting bolt (1) and pivot bolt (2) to the generator.
4. Install the drive belt to the pulleys.
5. Remove slack from the belt by pulling on the generator in order to obtain 9-11 mm (0.35-0.43 in) of belt deflection under 10 kg (22 lbs) of force.
6. Secure the generator with the adjusting bolt and pivot bolt.

Tighten
Tighten the generator bolts to 23 N.m (17 lb ft).

7. Connect the electrical connector to the generator B+ terminal. Secure the connector with one nut and the rubber protector.

Tighten
Tighten the electrical connector nut to 8 N.m (71 lb in).

8. Connect the generator electrical connector.
9. Install the air cleaner hose.

10. Connect the negative battery cable. 

Tighten
Tighten the negative battery cable-to-negative battery terminal retainer to 8 N.m (71 lb in).