chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

HVAC System - Manual|Page 14011 > < HVAC System - Manual|Page 14009
Page 1
background image

Air Door Actuator / Motor: Service and Repair
HVAC System - Automatic

Recirculation Actuator

RECIRCULATION ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the HVAC module assembly. 
2. Remove the screws from the air inlet assembly.
3. Remove the air inlet assembly.

4. Disconnect the recirculation actuator electrical connector
5. Remove the recirculation actuator screws.
6. Remove the recirculation actuator.

INSTALLATION PROCEDURE

1. Install the recirculation actuator.
2. Install the air inlet assembly.
3. Install the recirculation actuator screws. 

Tighten the screws to 1.9 N.m (17 lb in).

NOTE:  Refer to Fastener Notice.

4. Connect the recirculation actuator electrical connector.
5. Install the HVAC module assembly. 
6. Recalibrate the recirculation actuator on vehicles equipped with automatic climate control (C68).  See: Testing and Inspection/Programming and

Relearning

Mode Actuator

MODE ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the left side sound insulator screws.
2. Remove the left hand floor duct. 

HVAC System - Manual|Page 14011 > < HVAC System - Manual|Page 14009