1. Position the recirculation door actuator (1) into the vehicle.
2. Install the recirculation door actuator onto the HVAC air inlet housing (2). If necessary, rotate the actuator slightly to align the splines on the

actuator output shaft (3) with those on the recirculation door pivot shaft (4).

3. Install the screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 Nm (17 in. lbs.).
4. Connect the HVAC wire harness connector (4) to the recirculation door actuator.
5. Install the glove box into the instrument panel See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument

Panel Glove Box - Installation.

6. Reconnect the negative battery cable.