chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Relays and Modules - Lighting and Horns > < A/C - Erratic Operation/Poor Performance|Page 119
Page 1
background image

Control Module HVAC: Service and Repair

BLOWER MOTOR POWER MODULE REPLACEMENT 

REMOVAL

The Blower Motor Power Module is used on ATC systems only.

Negative Battery Cable Remote Terminal

1. Open hood and disconnect the negative battery cable remote terminal from the remote battery post.
2. Remove lower right underpanel silencer/duct.
3. Disconnect wiring connectors on blower motor resistor.
4. Remove blower motor resistor retaining screws.
5. Pull blower motor resistor out of heater housing.

INSTALLATION

For installation, reverse the above procedures.

Relays and Modules - Lighting and Horns > < A/C - Erratic Operation/Poor Performance|Page 119