9. Disconnect downstream oxygen sensor connector and remove sensor from converter pipe. 

10. Loosen and remove V-Band clamp at exhaust manifold.

NOTE:  Do not reuse V-Band clamp.

11. Remove converter from engine compartment.

INSTALLATION - RIGHT SIDE 

1. Position a NEW V-Band clamp onto the exhaust manifold outlet. DO NOT latch the clamp's T-bolt at this time.
2. Install catalytic converter. If necessary, stretch open the V-Band clamp to allow the converter to engage the manifold outlet.
3. Latch the V-Band clamp T-bolt.
4. Raise vehicle on hoist.
5. Install right side converter extension pipe, but do not tighten clamp at this time.
6. Lower vehicle on hoist.

NOTE:  Check for proper alignment and clearance to underbody and engine compartment components before tightening clamps.

7. Tighten V-Band clamp to 11 Nm (100 inch lbs.).
8. Install downstream oxygen sensor and connect electrical connector. 
9. Install Short Runner Valve (SRV) vacuum reservoir and control valve assembly at right rear of engine (3.2/3.5L, engine only).

10. Install air cleaner assembly with air inlet hose.
11. Raise vehicle on hoist.
12. Tighten extension pipe band clamp to 61 Nm (45 ft. lbs.).
13. Install and/or tighten nut attaching extension pipe to transaxle bracket to 47 Nm (35 ft. lbs.).
14. Install exhaust system.
15. Lower vehicle.