Blend Door Actuator Replacement|Page 4739 > < Blend Door Actuator Replacement
Page 2
background image

Fig.16 Blend Door Actuator Location

3. Remove the two screws from the actuator which are accessible from the right side of the center stack.
4. Remove one screw from actuator on the left side.
5. Pull the actuator straight down from shaft and disconnect the electrical connection. Upon removal, note the shaft position of the actuator, because

the shaft on this motor is keyed. When installing a new actuator, its shaft must be positioned in the same location.

INSTALLATION

1. Connect the wire harness connector to the blend door actuator.
2. Install the blend door actuator on the HVAC housing, making sure its keyed shaft is positioned properly.
3. Install the three fastener screws and tighten to 2.2 Nm (20 in. lbs.).
4. Install the left and right underpanel silencer/ducts.
5. Connect the negative battery cable remote terminal to the remote battery post.

Blend Door Actuator Replacement|Page 4739 > < Blend Door Actuator Replacement