chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 4925
Page 1
background image

Refrigerant: Testing and Inspection

WARNING:  REVIEW THE WARNINGS BEFORE PERFORMING THE FOLLOWING OPERATION.

If the refrigerant system is empty or low in refrigerant charge, a leak at any line fitting or component seal is likely. A review of the fittings, lines and
components for oily residue is an indication of the leak location. To detect a leak in the refrigerant system, perform one of the following procedures as
indicated by the symptoms.

EMPTY REFRIGERANT SYSTEM LEAK TEST

1. Evacuate the refrigerant system (minimum evacuation time of 15 mm.) to the lowest degree of vacuum possible (approx. 28 in Hg.). Determine if

the system holds a vacuum for at least 15 minutes after pump is OFF. If vacuum is held, a leak is probably not present. If system will not maintain
vacuum level, proceed with this procedure.

2. Prepare a .284 Kg. (10 oz.) refrigerant charge to be injected into the system.
3. Connect and dispense .284 Kg. (10 oz.) of refrigerant into the evacuated refrigerant system.
4. Proceed to Step 2 of Low Refrigerant Level Leak Test.

LOW REFRIGERANT LEVEL LEAK TEST

1. Determine if there is any (R-134a) refrigerant in the system.
2. Position the vehicle in a wind free work area. This will aid in detecting small leaks.
3. Bring the refrigerant system up to operating temperature and pressure. This is done by allowing the engine to run for five minutes with the system

set to the following:
-

Transaxle in Park

-

Engine Idling

-

A/C Controls Set in 100 percent outside air

-

Blower switch in the high A/C position

-

A/C in the ON position

-

Open all windows

CAUTION:
-

A leak detector designed for R-12 refrigerant may not detect leaks in a R-1 34a refrigerant system. Check specifications on leak detector.

4. Shut OFF the vehicle and wait 2 to 7 minutes. Then use an Electronic Leak Detector that is designed to detect R-134a type refrigerant and search

for leaks. Fittings, lines, or components that appear to be oily usually indicates a refrigerant leak. To inspect the evaporator core for leaks, insert
the leak detector probe into the drain tube opening or a heat duct.

NOTE:  If leak is not detected but known to exist, further diagnosis may be necessary using a refrigerant dye and the recovery machine. Refer to
recovery machine instructions for proper dye infection procedures.

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 4925