Fig.10 Negative Battery Cable Remote Terminal
REMOVAL
1. Open hood and disconnect the negative battery cable remote terminal from the remote battery post.
2. Disconnect the wire harness connector from the a/c pressure transducer.
CAUTION:
-
A slight release of pressure trapped in the fitting may be experienced. It is not necessary to discharge the refrigerant system.
3. Remove the transducer with a counterclockwise rotation using a 14 mm open-end wrench.
INSTALLATION
1. Install the a/c pressure transducer on the discharge line fitting and tighten to 6 Nm (50 in. lbs.).
2. Plug in the wire harness connector to the a/c pressure transducer.
3. Connect the battery negative cable to the remote battery post.