chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Ignition System > < Variable Induction Control Valve|Specifications|Page 3085
Page 1
background image

Variable Induction Control Valve: Service and Repair

REMOVAL

1. Disconnect negative battery cable.

Fig. 14 Manifold Tuning Valve

2. Disconnect electrical connector (Fig. 14).

Fig. 15 Manifold Tuning Valve Removal/Installation

3. Remove manifold tuning valve mounting screws. Remove tuning valve (Fig. 15).

INSTALLATION

1. Install tuning valve. Tighten mounting screws to 11.9 Nm (105 in. lbs.) torque.
2. Install electrical connector.
3. Connect negative battery cable.

Ignition System > < Variable Induction Control Valve|Specifications|Page 3085