Canister Purge Solenoid: Locations

EVAP/PURGE SOLENOID

Fig. 2 UPSTREAM HEATED OXYGEN SENSOR III

1. PROPORTIONAL PURGE SOLENOID
2. 02 SENSOR
The top of the solenoid has TOP printed on it. The solenoid will not operate unless it is installed correctly.

(1) Install solenoid on bracket.
(2) Connect vacuum tube to solenoid.
(3) Connect electrical connector to solenoid.